More on circuit breakers.
Old style old circuit breaker.
The qo 20 amp tandem single pole replacement circuit breaker offers 2 poles in the space of 1.
Discard the old circuit breaker.
Breaker king ch old style slotted used ch115slottedut cutler hammer 1p 15a 120v 10k circuit breaker.
If you have an old or hard to find breaker you need to replace give us a call at 1 800 699 2980 or request a quote we have used and obsolete breakers coming in all the time.
Bay breakers has been specializing in new reconditioned and hard to find obsolete replacement circuit breaker options for over 20 years.
Pioneer breaker control supply is a wholesaler of circuit breakers fuses contactors motor starters and many other key electrical products.
Finding old or obsolete general electric circuit breakers can be challenging.
Ge has produced circuit breakers for over 70 years which can make it difficult to match the right models and model numbers to your needs.
The breaker shipped and arrived quickly and was just as described and expected.
More info sold out.
Arc fault circuit interrupter afci circuit breakers protect against an unintentional electrical discharge in an electrical cord or wiring that could cause a fire once the breaker senses the electrical jump and abnormal path it instantly disconnects the damaged circuit before the arc builds enough heat to catch fire.
Learn about general nec 2020 updates.
The replacement breaker is for use in old style non class ctl qo load centers and has a maximum load of 240 volt.
Old style branch characterized by the tan handle and slotted cut out.
Afci and gfci circuit breakers work against arc and ground faults respectively.
Home heater overloads cutler hammer westinghouse heater overloads 8586h old style cutler hammer sort by.
Place a new one in the same spot as the old one.
The breaker features qwik open and a visi trip indicator to easily identify a tripped breaker.
The square d qo 20 amp tandem single pole replacement circuit breaker offers 2 poles in the space of 1 for use in old style non class ctl qo load centers.
Cutler hammer 3p 100a 240v 10k main circuit breaker.
Replace the panel s faceplate.
It is like having two breakers in one.
Ch main breaker old style.
Page of 1.
When a qo visi trip circuit breaker trips the handle snaps to a midpoint position between off and on and a highly visible red indicator easily identifies the tripped breaker.
This is a previously used circuit breaker that has undergone thorough inspection nema ab4 load testing and has been re qualified for return to service for the safe and reliable distribution and control.
This old style cutler hammer eaton corporation cht 2020 circuit breaker was perfect for adding a second 20 amp breaker into one circuit breaker slot.
Old style main characterized by the tan handle.
H1338 r ch cutler hammer heater overload h1339 ch.
Cutler hammer 2p 60a 240v 10k circuit breaker.
Remove the circuit breaker.